PROFINET Protocol Converter

MODBUS to PN protocol converter AB-PN-MMDAA

MODBUS to PN protocol converter AB-PN-MMDAA

Product Details

Product name: MODBUS to PN protocol converter AB-PN-MMDAA

Features:

    PROFINET Interface Features:

  • A 2-port switch is integrated.
  • Supported Ethernet services: ping, arp, SNMP, and LLDP.
  • Port diagnostics.
  • Disable the port.
  • Real-time, isochronous real-time communication (RT, IRT).
  • Minimum update time 250μs.
  • Prioritize startup.
  • Media Redundancy (MRP).
  • Media redundancy with planned replication (MRPD) is supported.
  • Shared devices supporting up to 2 IO controllers.
  • Identification data I&M 0 to 5.

         MODBUS Interface Features:

  • Support Modbus RTU protocol, support 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H function codes.
  • The physical layer supporting Modbus RTU protocol is RS485 or RS232 interface.
  • MODBUS interface bus parameters (baud rate, character format, etc.) can be selected.
  • 4-way MODBUS interface bus parameters are independently set, and MODBUS devices with different baud rate, character format and other parameters can be connected to the same module.
  • With MODBUS device automatic plug-in function
  • You can set the number of times the message is sent repeatedly when the MODBUS communication fails.
  • The maximum response time of MODBUS communication, the maximum interval time of characters, and the interval time of message sending can be set.

Specifications:

  • Compliant with ROFINET/V2.2 protocol, PROFINET interface realizes RT and IRT communication, conforms to: GB/T25105-2014 “Industrial Communication Network Fieldbus Specification Type 10: PROFINET IO Specification”, IEC61158-5-10: 2007, IDT.
  • Comply with Modbus RTU synchronous protocol standard GB/T 19582-2008 (industrial automation network specification based on Modbus protocol).
  • Connect the device with RS232/485 interface and MODBUS protocol interface to PROFINET IO as a device of PROFINET field bus system.
  • 24 VDC power supply (wide voltage: 18 to 36 VDC).
  • Use the RJ45 bus connector to connect PROFINET IO.
  • Each module has a total of 512 bytes of I/O data.
  • Each module has 4 independent RS485/RS232 interfaces, which can connect 59 slave devices.
  • 24 VDC power supply, RJ45 interface, RS232 interface, RS485 interface, and internal circuits are isolated from each other.
  • The PROFINET bus data area (I/O area) and the MODBUS bus data area (0, 1, 3, 4) establish a mapping relationship to realize the transparent transmission of PROFINET bus data and MODBUS bus data.